Arch 3008 Spring 2018


Are a visible form of energy carried by electromagnetic waves?



Source Material + Vocabulary  

Illumination  

Source material: MEEB_ Lighting Fundamentals Case studies: James Turrell ­ skyspace / light show Vocabulary: 

1. Radiant Energy: a form of energy that permits us to see. Surfaces can also permit this kind of light which are waves with various frequencies.

2. Rods and Cones: light­sensitive cells located in the retina of the eye

a. Rods:  photoreceptor cells that can function in less intense light than cone cells. Usually concentrated at the outer edges of the retina and are used in peripheral vision.  Rods are extremely light sensitive, but lack color sensitivity, so in dim light (rod vision), we have no color perception and all colors appear as varying shades of gray. These cells also lack detail discrimination, making “night vision” coarse. Rod cells are slower acting than cone cells and therefore have a low degree of flicker fusion, so they are highly motion sensitive. This results in our being best able to detect movement when looking out of the “corner of the eye.” 


Where are the rods and cones in the eye?



Don't forget about the age old question of It is the rate at which inflation occurs. what is it?

b. Cones: The central portion of the eye, near the fovea, is an area of pinhead size containing about 100,000 cone cells, which accounts for the extreme precision of foveal (center‐focus) vision. The cones enable us to discriminate detail; they also give us the capacity to perceive color,   and   can   detect  luminances.   Cones   are   extremely   narrow   which   allows   for   such perception of detail. We also discuss several other topics like Who invented the first compound microscope?

3. Color Temperature:  the temperature to which a blackbody must be heated to radiate a light similar in color to the color of the source in question. The color of the light radiated from a light source is related to its temperature. a color temperature can be assigned only to a light source that produces light by heating, such as the incandescent lamp. 

4. Color   Rendering   Index   (CRI):  a   two‐part   concept,   comprising   a   color   temperature   that establishes   the   reference   standard,   and   a   number   that   indicates   how   closely   the   illuminant approaches the standard. Two sources cannot be com­ pared unless their color temperatures are equal or quite close.


How is the temperature of an object related to the color of light it emits?



5. Lumen (output): The unit of luminous flux, in both SI and I‐P units, is the lumen. Also known as a unit of eye‐perceived, or photo­ metric, power. A lumen/lumen flux is the time rate of flow of perceived luminous energy. This unit of measurement is like that of a watt. Output decreases slowly with lamp life as an incandescent bulb blackens. Lamp position (vertical or horizontal) during operation and the resulting bulb temperatures affect this characteristic.

6. Illuminance (LUX reaching surface):  the density of luminous power, expressed in terms of lumens per unit area. Normally represented by the letter E.  If you want to learn more check out Define a consumer.

7. Luminance (reflection that we see):  subjective brightness and brightness contrasts caused by photometric luminance. Lux meters are cheaper and simpler to use than luminance meters.

8. Reflection vs Transmittance We also discuss several other topics like Define ethnography.

Arch 3008 Spring 2018

Source Material + Vocabulary  

a. Reflection: the ratio of reflected light to incident light. if half the amount of light incident on a surface is bounced back, the reflectance is 50% (or 0.50). The remainder is absorbed, transmitted, or both. The amount of absorption and reflection depends on the type of material and the angle of light incidence, because light impinging on a surface at grazing angles tends to be reflected rather than absorbed or transmitted  Don't forget about the age old question of What is the third planet from the sun?

b. Transmittance: a measure of its capability to transmit incident light. By definition, this quantity, known variously as transmittance, transmission factor, and coefficient of transmission, is the ratio of the total transmitted light to the total incident light.  We also discuss several other topics like Who are hooke, leeuwenhoek, abbe, zeiss?

Daylighting 

Source material: MEEB_ Designing for Heating and Cooling; Daylighting Design Case studies: Assmann, Salomon, & Scheidt_Marzahn Low­Energy apartment; Jones Studio_University of Arizona School of Arch + Landscape Arch

Vocabulary: 

1. Direct vs Diffused Natural light 

a. Direct—creates various intensities of light from all directions—therefore yielding shadows.

b. Diffused—creates equal intensities of light impinging from all directions—therefore yielding no shadows. 

2. Daylight Factor— expressed as the ratio of interior illuminance (Ei) to available outdoor  illuminance (EH) under overcast skies. applicable only where the sky luminance distribution is  known or can reasonably be estimated. Cannot be used with skies with constantly changing  luminance (partly cloudy and direct sun) because under such conditions the daylight factor at a  given point also varies continuously, making the concept useless as a calculation tool for absolute daylight values. This factor is constant for a given space and window configuration. Allows  determination of interior daylight distribution for varying fenestration, spatial arrangement, and  building orientation. 

Arch 3008 Spring 2018

Source Material + Vocabulary  

3. DFH vs DFV: the x and y components of the Daylight Factor in relation to a window in a given  space

a. DFH—The total Daylight Factor as measured horizontally

b. DFV— The total Daylight Factor as measured vertically

4. LUX levels: Illuminance is measured in lux units. Variables include latitude and external  illuminance (lm/ft2). 

5. 2.5H vs 15/30 Guideline 

a. 2.5H— the lighting design field (Fig. 8.30) assumes that there will be sufficient work plane  illuminance from a window up to a dis­ tance of 2.5 times the head height of the window  above the work plane—assuming clear glazing, overcast skies, no major obstructions, and a  total window width that is approximately half that of the exterior perimeter wall. 

b. 15/30 Guideline— guideline assumes that a 15‐ft‐wide (4.6‐m) zone from a window wall  (Fig. 8.31) can be daylit sufficiently for office tasks. The next 15‐ft (4.6‐m) zone can be  partially day­ lit and supplemented with electric lighting.

6. CIE Method­Graph:  The diagrams give the lowest level of daylight that can reliably be  expected for a given percentage (percentile) of normal working hours in sidelighted rooms and  the average level in toplighted spaces. Based upon the daylight factor. The curves relate  minimum daylight factor to the maximum permissible room depth, for given reflectance and a  standard window design, thus establishing the room’s proportions. Depth, or width, is the  dimension at right angles to the window wall. 

a. Advantages: 

∙ It allows consideration of obstructions, exterior reflections, and interior reflections.  ∙ It is applicable to a very wide range of side and top fenestration designs. 

∙ Establishment of required room proportions is architecturally more useful than solving  for specific dimensions. 

b. Limitations: 

∙ It is inapplicable to clear‐sky and direct‐sun conditions. 

∙ It is inapplicable to other than rectangular rooms. 

∙ It is unusable with sunshading devices or high‐reflectance ground.

∙ Results give points of minimum, twice minimum, and four times minimum daylight only. Other points must be interpolated or extrapolated.

∙ Window proportions and position in a wall are fixed. 