A Y-connected load bank with a three-phase rating of 500
Chapter , Problem 8.12(choose chapter or problem)
A Y-connected load bank with a three-phase rating of 500 kVA and 2300 V consists of three identical resistors of 10.58 W. The load bank has the following applied voltages: Vab _ 1840 82:8 , Vbc _ 2760 ?41:4 , and Vca _ 2300 180 V. Determine the symmetrical components of (a) the line-to-line voltages Vab0, Vab1, and Vab2; (b) the line-to-neutral voltages Van0, Van1, and Van2; (c) and the line currents Ia0, Ia1, and Ia2. (Note that the absence of a neutral connection means that zero-sequence currents are not present.) S