Unless otherwise indicated, for problems in | Ch 17 - 79PE

College Physics by Urone | 1st Edition | ISBN: 9781938168000 | Authors: Paul Peter Urone

Problem 79PE Chapter 17

College Physics by Urone | 1st Edition

  • 2901 Step-by-step solutions solved by professors and subject experts
  • Get 24/7 help from StudySoup virtual teaching assistants
College Physics by Urone | 1st Edition | ISBN: 9781938168000 | Authors: Paul Peter Urone

College Physics by Urone | 1st Edition

4 5 0 319 Reviews
31
1
Problem 79PE

Unless otherwise indicated, for problems in this section, assume that the speed of sound through human tissues is 1540 m/s.

(a) Echo times are measured by diagnostic ultrasound scanners to determine distances to reflecting surfaces in a patient. What is the difference in echo times for tissues that are 3.50 and 3.60 cm beneath the surface? (This difference is the minimum resolving time for the scanner to see details as small as 0.100 cm, or 1.00 mm. Discrimination of smaller time differences is needed to see smaller details.) (b) Discuss whether the period T of this ultrasound must be smaller than the minimum time resolution. If so, what is the minimum frequency of the ultrasound and is that out of the normal range for diagnostic ultrasound?

Step-by-Step Solution:
Step 1 of 3

Solution 79PE

The value of the difference in echo times for tissues is 1.30 x The...
Step 2 of 3

Chapter 17, Problem 79PE is Solved
Step 3 of 3

Textbook: College Physics by Urone
Edition: 1st
Author: Paul Peter Urone
ISBN: 9781938168000

The answer to “Unless otherwise indicated, for problems in this section, assume that the speed of sound through human tissues is 1540 m/s.(a) Echo times are measured by diagnostic ultrasound scanners to determine distances to reflecting surfaces in a patient. What is the difference in echo times for tissues that are 3.50 and 3.60 cm beneath the surface? (This difference is the minimum resolving time for the scanner to see details as small as 0.100 cm, or 1.00 mm. Discrimination of smaller time differences is needed to see smaller details.) (b) Discuss whether the period T of this ultrasound must be smaller than the minimum time resolution. If so, what is the minimum frequency of the ultrasound and is that out of the normal range for diagnostic ultrasound?” is broken down into a number of easy to follow steps, and 125 words. Since the solution to 79PE from 17 chapter was answered, more than 310 students have viewed the full step-by-step answer. College Physics by Urone was written by Sieva Kozinsky and is associated to the ISBN: 9781938168000. This full solution covers the following key subjects: ultrasound, minimum, smaller, difference, diagnostic. This expansive textbook survival guide covers 34 chapters, and 3125 solutions. This textbook survival guide was created for the textbook: College Physics by Urone, edition: 1st. The full step-by-step solution to problem: 79PE from chapter: 17 was answered by Sieva Kozinsky, our top Physics solution expert on 07/07/17, 04:39PM.

×
Log in to StudySoup
Get Full Access to College Physics By Urone - 1st Edition - Chapter 17 - Problem 79pe

Forgot password? Reset password here

Join StudySoup for FREE
Get Full Access to College Physics By Urone - 1st Edition - Chapter 17 - Problem 79pe
Join with Email
Already have an account? Login here
Reset your password

I don't want to reset my password

Need help? Contact support

Need an Account? Is not associated with an account
Sign up
We're here to help

Having trouble accessing your account? Let us help you, contact support at +1(510) 944-1054 or support@studysoup.com

Got it, thanks!
Password Reset Request Sent An email has been sent to the email address associated to your account. Follow the link in the email to reset your password. If you're having trouble finding our email please check your spam folder
Got it, thanks!
Already have an Account? Is already in use
Log in
Incorrect Password The password used to log in with this account is incorrect
Try Again

Forgot password? Reset it here