Solved: an X Ray X rays are a very penetrating form of

Chapter 12, Problem 7P

(choose chapter or problem)

Get Unlimited Answers
QUESTION:

an X Ray X rays are a very penetrating form of electromagnetic radiation. X rays pass through the soft tissue of the body but are largely stopped by bones and other more dense tissues. This makes x rays very useful for medical and dental purposes, as you know. A schematic view of an x-ray tube and a driver circuit is given in Figure VI.1. A filament warms the cathode, freeing electrons. These electrons are accelerated by the electric field established by a high-voltage power supply connected between the cathode and a metal target. The electrons accelerate in the direction of the target. The rapid deceleration when they strike the target generates x rays. Each electron will emit one or more x rays as it comes to rest. An x-ray image is essentially a shadow; x rays darken the film where they pass, but the film stays unexposed, and thus light, where bones or dense tissues block x rays. An x-ray technician adjusts the quality of an image by adjusting the energy and the intensity of the x-ray beam. This is done by adjusting two parameters: the accelerating voltage and the current through the tube. The accelerating voltage determines the energy of the x-ray photons, which can’t be greater than the energy of the electrons. The current through the tube determines the number of electrons per second and thus the number of photons emitted. In clinical practice, the exposure is characterized by two values: “kVp” and “mAs.” kVp is the peak voltage in kV. The value mAs is the product of the current (in mA) and the time (in s) to give a reading in mA . s. This is a measure of the total number of electrons that hit the target and thus the number of x rays emitted. Typical values for a dental x ray are a kVp of 70 (meaning a peak voltage of 70 kV) and mAs of 7.5 (which comes from a current of 10 mA for 0.75 s, for a total of 7.5 mAs). Assume these values in all of the problems that follow. If the distance between the cathode and the target electrode is approximately 1.0 cm, what will be the maximum acceleration of the free electrons? Assume that the electric field is uniform.

Questions & Answers

QUESTION:

an X Ray X rays are a very penetrating form of electromagnetic radiation. X rays pass through the soft tissue of the body but are largely stopped by bones and other more dense tissues. This makes x rays very useful for medical and dental purposes, as you know. A schematic view of an x-ray tube and a driver circuit is given in Figure VI.1. A filament warms the cathode, freeing electrons. These electrons are accelerated by the electric field established by a high-voltage power supply connected between the cathode and a metal target. The electrons accelerate in the direction of the target. The rapid deceleration when they strike the target generates x rays. Each electron will emit one or more x rays as it comes to rest. An x-ray image is essentially a shadow; x rays darken the film where they pass, but the film stays unexposed, and thus light, where bones or dense tissues block x rays. An x-ray technician adjusts the quality of an image by adjusting the energy and the intensity of the x-ray beam. This is done by adjusting two parameters: the accelerating voltage and the current through the tube. The accelerating voltage determines the energy of the x-ray photons, which can’t be greater than the energy of the electrons. The current through the tube determines the number of electrons per second and thus the number of photons emitted. In clinical practice, the exposure is characterized by two values: “kVp” and “mAs.” kVp is the peak voltage in kV. The value mAs is the product of the current (in mA) and the time (in s) to give a reading in mA . s. This is a measure of the total number of electrons that hit the target and thus the number of x rays emitted. Typical values for a dental x ray are a kVp of 70 (meaning a peak voltage of 70 kV) and mAs of 7.5 (which comes from a current of 10 mA for 0.75 s, for a total of 7.5 mAs). Assume these values in all of the problems that follow. If the distance between the cathode and the target electrode is approximately 1.0 cm, what will be the maximum acceleration of the free electrons? Assume that the electric field is uniform.

ANSWER:

Solution Introduction: F Acceleration and force are related as, a =m , where a is acceleration, F is the force on an electron and m is its mass. We know the charge of an electron, so if we can calculate force if we can calculate the electric field strength. Electric field strength can be calculated if voltage and separation between electrodes is given. Step 1: Electric field, E = Voltage …..(1) Separation between the electrodes Given that, Voltage = 70kV Distance between electrodes = 1.0 cm 2 = 10 m Therefore, Electric field, E =702 (from equation 1) 10 m E = 70×1000×10 2 m 6V E = 7×10 m …..(2)

Add to cart


Study Tools You Might Need

Not The Solution You Need? Search for Your Answer Here:

×

Login

Login or Sign up for access to all of our study tools and educational content!

Forgot password?
Register Now

×

Register

Sign up for access to all content on our site!

Or login if you already have an account

×

Reset password

If you have an active account we’ll send you an e-mail for password recovery

Or login if you have your password back