Analyzing Thermodynamic CyclesA refrigeration cycle

Chapter 2, Problem 85P

(choose chapter or problem)

Get Unlimited Answers
QUESTION:

A refrigeration cycle operating as shown in Fig. 2.17b has \(Q_{\text {out }}=1000 \mathrm{Btu}\) and \(W_{\text {cycle }}=300 \mathrm{Btu}\). Determine the coefficient of performance for the cycle.

Questions & Answers

QUESTION:

A refrigeration cycle operating as shown in Fig. 2.17b has \(Q_{\text {out }}=1000 \mathrm{Btu}\) and \(W_{\text {cycle }}=300 \mathrm{Btu}\). Determine the coefficient of performance for the cycle.

ANSWER:

Solution 85P

Step 1 of 3

Here we need to calculate the coefficient of performance for given refrigeration cycle.

Given data,

Heat transfer of energy out of system,

Net work output,

To find,

Heat transfer of energy into the system,

Coefficient of performance,