The rate of heat transfer to the surroundings from a

Chapter 3, Problem 194HP

(choose chapter or problem)

Get Unlimited Answers
QUESTION:

Problem 194HP

The rate of heat transfer to the surroundings from a person at rest is about 400 kJ/h. Suppose that the ventilation system fails in an auditorium containing 100 people. Assume the energy goes into the air of volume 1500 m3 initially at 300 K and 101 kPa. Find the rate (degrees per minute) of the air temperature change.

Questions & Answers

QUESTION:

Problem 194HP

The rate of heat transfer to the surroundings from a person at rest is about 400 kJ/h. Suppose that the ventilation system fails in an auditorium containing 100 people. Assume the energy goes into the air of volume 1500 m3 initially at 300 K and 101 kPa. Find the rate (degrees per minute) of the air temperature change.

ANSWER:

Solution 194 HP

Step 1 of 4

To find the rate of change in temperature of air in an auditorium.