Mixing ProcessesAgeothermal supply of hotwater at 500 kPa,
Chapter 4, Problem 111HP(choose chapter or problem)
Problem 111HP
Mixing Processes
Ageothermal supply of hotwater at 500 kPa, 150°C is fed to an insulated flash evaporator at the rate of 1.5 kg/s. A stream of saturated liquid at 200 kPa is drained from the bottom of the chamber, and a stream of saturated vapor at 200 kPa is drawn from the top and fed to a turbine. Find the mass flow rate of the two exit flows.
Questions & Answers
QUESTION:
Problem 111HP
Mixing Processes
Ageothermal supply of hotwater at 500 kPa, 150°C is fed to an insulated flash evaporator at the rate of 1.5 kg/s. A stream of saturated liquid at 200 kPa is drained from the bottom of the chamber, and a stream of saturated vapor at 200 kPa is drawn from the top and fed to a turbine. Find the mass flow rate of the two exit flows.
ANSWER:
Solution 111 HP
Step 1 of 5:
In this question, we need to find mass flow rate of the two exit flows for geothermal supply
Data given
Temperature of hot water
Pressure
Rate of evaporation
Pressure of saturated liquid
Pressure of saturated vapor