A water cooler for drinking water should cool 25 L/h water

Chapter 5, Problem 32HP

(choose chapter or problem)

Get Unlimited Answers
QUESTION:

Problem 32HP

A water cooler for drinking water should cool 25 L/h water from 18°C to 10°C while the water reservoirs also gains 60 W from heat transfer. Assume that a small refrigeration unit with a COP of 2.5 does the cooling. Find the total rate of cooling required and the power input to the unit.

Questions & Answers

QUESTION:

Problem 32HP

A water cooler for drinking water should cool 25 L/h water from 18°C to 10°C while the water reservoirs also gains 60 W from heat transfer. Assume that a small refrigeration unit with a COP of 2.5 does the cooling. Find the total rate of cooling required and the power input to the unit.

ANSWER:

Solution 32 HP

Step 1 of 5

We are required to find the total rate of cooling and power input