Design a scalding unit for slaughtered chickens to loosen | StudySoup

Textbook Solutions for Thermodynamics: An Engineering Approach

Chapter 5 Problem 5212

Question

Design a scalding unit for slaughtered chickens to loosen their feathers before they are routed to feather-picking machines with a capacity of 1200 chickens per hour under the following conditions: The unit will be of an immersion type filled with hot water at an average temperature of 538C at all times. Chicken with an average mass of 2.2 kg and an average temperature of 368C will be dipped into the tank, held in the water for 1.5 min, and taken out by a slow-moving conveyor. The chicken is expected to leave the tank 15 percent heavier as a result of the water that sticks to its surface. The center-to-center distance between chickens in any direction will be at least 30 cm. The tank can be as wide as 3 m and as high as 60 cm. The water is to be circulated through and heated by a natural gas furnace, but the temperature rise of water will not exceed 58C as it passes through the furnace. The water loss is to be made up by the city water at an average temperature of 168C. The walls and the floor of the tank are well-insulated. The unit operates 24 h a day and 6 days a week. Assuming reasonable values for the average properties, recommend reasonable values for (a) the mass flow rate of the makeup water that must be supplied to the tank, (b) the rate of heat transfer from the water to the chicken, in kW, (c) the size of the heating system in kJ/h, and (d) the operating cost of the scalding unit per month for a unit cost of $1.12/therm of natural gas.

Solution

Step 1 of 5)

The first step in solving 5 problem number 212 trying to solve the problem we have to refer to the textbook question: Design a scalding unit for slaughtered chickens to loosen their feathers before they are routed to feather-picking machines with a capacity of 1200 chickens per hour under the following conditions: The unit will be of an immersion type filled with hot water at an average temperature of 538C at all times. Chicken with an average mass of 2.2 kg and an average temperature of 368C will be dipped into the tank, held in the water for 1.5 min, and taken out by a slow-moving conveyor. The chicken is expected to leave the tank 15 percent heavier as a result of the water that sticks to its surface. The center-to-center distance between chickens in any direction will be at least 30 cm. The tank can be as wide as 3 m and as high as 60 cm. The water is to be circulated through and heated by a natural gas furnace, but the temperature rise of water will not exceed 58C as it passes through the furnace. The water loss is to be made up by the city water at an average temperature of 168C. The walls and the floor of the tank are well-insulated. The unit operates 24 h a day and 6 days a week. Assuming reasonable values for the average properties, recommend reasonable values for (a) the mass flow rate of the makeup water that must be supplied to the tank, (b) the rate of heat transfer from the water to the chicken, in kW, (c) the size of the heating system in kJ/h, and (d) the operating cost of the scalding unit per month for a unit cost of $1.12/therm of natural gas.
From the textbook chapter Mass and Energy Analysis of Control Volumes you will find a few key concepts needed to solve this.

Step 2 of 7)

Visible to paid subscribers only

Step 3 of 7)

Visible to paid subscribers only

Subscribe to view the
full solution

Title Thermodynamics: An Engineering Approach  8 
Author Yunus A. Cengel, Michael A. Boles
ISBN 9780073398174

Design a scalding unit for slaughtered chickens to loosen

Chapter 5 textbook questions

×

Login

Organize all study tools for free

Or continue with
×

Register

Sign up for access to all content on our site!

Or continue with

Or login if you already have an account

×

Reset password

If you have an active account we’ll send you an e-mail for password recovery

Or login if you have your password back